COMPANY HEADER
Terms
Safety relays in the PNOZelog product range monitor E-STOP, safety gates or light grids. You can identify the delay-on de-energization units by the v in the product name, e.g. PNOZ e1vp. These can also be used as timers. With the exception of the PNOZ e1p, all units have an AND-OR input for logic interconnections between units. The supply voltage is 24 VDC, the width is 22.5 mm (PNOZ e6.1p/e6vp 45 mm).
Request Information
Unit of Measure
Items
PNOZelog 22.5 mm Depth Emergency Stop, Gates, and Light Grids Monitoring Safety Relay (774130)

PNOZelog 22.5 mm Depth Emergency Stop, Gates, and Light Grids Monitoring Safety Relay
List Price $205.80

PNOZelog 22.5 mm Depth Emergency Stop, Gates, and Light Grids Monitoring Safety Relay (774131)

PNOZelog 22.5 mm Depth Emergency Stop, Gates, and Light Grids Monitoring Safety Relay
List Price $318.28

PNOZelog 22.5 mm Depth Emergency Stop, Gates, and Light Grids Monitoring Safety Relay (774132)

PNOZelog 22.5 mm Depth Emergency Stop, Gates, and Light Grids Monitoring Safety Relay
List Price $318.28

PNOZelog 22.5 mm Depth Emergency Stop, Gates, and Light Grids Monitoring Safety Relay (774133)

PNOZelog 22.5 mm Depth Emergency Stop, Gates, and Light Grids Monitoring Safety Relay
List Price $234.05

PNOZelog 22.5 mm Depth Emergency Stop, Gates, and Light Grids Monitoring Safety Relay (774137)

PNOZelog 22.5 mm Depth Emergency Stop, Gates, and Light Grids Monitoring Safety Relay
List Price $313.49
Description N/A Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 2 safety outputs + 1 auxiliary output in semiconductor technology Automatic/monitored start, UB 24 VDC, width: 22.5 mm, Plug-in terminals of screw type, monitoring E-STOP, safety gates. N/A Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 2 safety outputs + 1 auxiliary output in semiconductor technology delayed Automatic/monitored start, UB 24 VDC, width: 22.5 mm, plug-in Terminals of screw type, connecting several devices, Monitoring E-STOP, safety gates. N/A Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 2 safety outputs + 1 auxiliary output in semiconductor technology delayed Automatic/monitored start, UB 24 VDC, width: 22.5 mm, plug-in Terminals of screw type, connecting several devices, Monitoring E-STOP, safety gates. N/A Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 2 safety outputs + 1 auxiliary output in semiconductor technology Automatic/monitored start, UB 24 VDC, width: 22.5 mm, plug-in Terminals of screw type, connecting several devices, Monitoring E-STOP, safety gates. N/A Safety relay (standalone) Inputs: 2-channel wiring with/without detection of shorts across contacts (PSEN 2.1p/2.2p) Outputs: 2 safety outputs + 1 auxiliary output in semiconductor technology, delayed Automatic/monitored start, UB 24 VDC, width: 22.5 mm, plug-in Terminals of screw type, connecting several devices, safety gate monitor Evaluation device for safety sensor.
Type N/A Monitoring Safety Relay
Certifications N/A European Conformity (CE), Tested to Canadian and US standards by Underwriters' Laboratories (cULus) Listed, EAC (Eurasian), TÜV
Application Options N/A Instantaneous Emergency Stop Monitoring, Limit Switch, Light Beam Device Monitor Type 2 with t/p, Light Beam Device Monitor Type 2 without t/p, Light Beam Device Monitor Type 4, Safety Gate Monitor N/A Instantaneous Emergency Stop Monitoring, Limit Switch, Light Beam Device monitor Type 2 with t/p, Light Beam Device Monitor Type 2 without t/p, Light Beam Device monitor Type 4, Safety Gate Monitor, Safe Delay-on de-Energization Timer, Delayed Emergency Stop Monitoring N/A Instantaneous Emergency Stop Monitoring, Limit Switch, Light Beam Device monitor Type 2 with t/p, Light Beam Device Monitor Type 2 without t/p, Light Beam Device monitor Type 4, Safety Gate Monitor, Safe Delay-on de-Energization Timer, Delayed Emergency Stop Monitoring N/A Instantaneous Emergency Stop Monitoring, Limit Switch, Light Beam Device Monitor Type 2 with t/p, Light Beam Device Monitor Type 2 without t/p, Light Beam Device Monitor Type 4, Safety Gate Monitor N/A Safety Gate Monitor, Non-Contact Safety Gate Monitor, Mechanical Safety Gate Monitor, Safe Delay-on de-energization Timer
Operating Modes N/A Single-Channel, Automatic Reset, Dual-Channel, Detection of Shorts Across Contacts, Start-up Testing, Monitored Manual Reset, without Detection of Shorts Across Contacts, Self Test N/A Single-Channel, Automatic Reset, Dual-Channel, Detection of Shorts Across Contacts, Start-Up Testing, Monitored Manual Reset, without Detection of Shorts Across Contacts, Self Test, Prog. Delay-on De-Energization, with and input, with or Input N/A Single-Channel, Automatic Reset, Dual-Channel, Detection of Shorts Across Contacts, Start-Up Testing, Monitored Manual Reset, without Detection of Shorts Across Contacts, Self Test, Prog. Delay-on De-Energization, with and input, with or Input N/A Single-Channel, Automatic Reset, Dual-Channel, Detection of Shorts Across Contacts, Start-Up Testing, Monitored Manual Reset, without Detection of Shorts Across Contacts, Self Test, with and Input, with or Input N/A Single-Channel, Automatic Reset, Dual-Channel, Detection of Shorts Across Contacts, Start-Up Testing, Monitored Manual Reset, without Detection of Shorts Across Contacts, Self Test, Prog. Delay-on De-Energization, with and input, with or Input
Standards N/A DIN V VDE 801-1/A1, European Standard (EN) 60204-1, European Standard (EN) 62061, European Standard (EN) International Organization for Standardization (ISO) 13849-1, VDE 0113-1, VDE 0116, European Standard (EN) 60947-5-1
Direct Current (DC) Supply Voltage N/A 24.0 V
Supply Voltage Type N/A Direct Current (DC)
Terminal Type N/A Screw Terminal
Terminal Style N/A Plug-in
Number of Safety Contacts N/A
Number of Instantaneous Safety Outputs N/A 2 Semiconductor Output either Instantaneous or Time Delayed N/A 1 Semiconductor Output either Instantaneous or Time Delayed N/A 1 Semiconductor Output either Instantaneous or Time Delayed N/A 2 Semiconductor Output either Instantaneous or Time Delayed N/A 1 Semiconductor Output either Instantaneous or Time Delayed
Number of Delayed Safety Outputs N/A N/A 1 Stop N/A 1 Stop N/A N/A 1 Stop
Number of Test Pulse Outputs N/A 2
Selectable Times N/A N/A 0.00 s0.15 s0.50 s1.00 s2.00 s3.00 s5.00 s7.00 s10.00 s N/A 0.00 s15.00 s25.00 s50.00 s100.00 s150.00 s200.00 s250.00 s300.00 s N/A N/A 0.00 s0.15 s0.50 s1.00 s2.00 s3.00 s5.00 s7.00 s10.00 s
Stop Category N/A 0 N/A 0 1 N/A 0 1 N/A 0 N/A 0 1
Current at DC13 I (6 cycles/min) [Max] N/A
Current at AC15 [Max] N/A
Width N/A 22.5 mm
Height N/A 90.5 mm N/A 94.0 mm N/A 94.0 mm N/A 94.0 mm N/A 94.0 mm
Depth N/A 121.0 mm
Gross Weight N/A 135 g N/A 145 g N/A 145 g N/A 145 g N/A 145 g
Net Weight N/A 120 g N/A 130 g N/A 130 g N/A 130 g N/A 130 g
Ambient Temperature [Min] N/A -10 ºC
Ambient Temperature [Max] N/A 55 ºC
Contact Configuration N/A
Number of Auxiliary Contacts N/A
Available Status N/A Available EX-Stock N/A Available EX-Stock N/A On Request N/A Available EX-Stock N/A On Request
Quantity N/A 1
Unit N/A PC
Short Description N/A PNOZ e1p 24VDC 2so N/A PNOZ e1vp 10/24VDC 1so 1so t N/A PNOZ e1vp 300/24VDC 1so 1so t N/A PNOZ e1.1p 24VDC 2so N/A PNOZ e3vp 10/24VDC 1so 1so t
Optional Accessories N/A , Set of Plug-In Replacement Terminal (QUOTE)
, PSS Terminal Block with Filter for 3 to 10 Kohm Load Range ($54.62)
, PSS Terminal Block with Filter for 10 to 30 Kohm Load Range ($54.62)