Type |
N/A Monitoring Safety Relay |
Contact Configuration |
N/A 3 Normally Open (N/O), 1 Normally Closed (N/C) |
Number of Semiconductor Outputs |
N/A 1 |
Available Status |
N/A On Request |
Quantity |
N/A 1 |
Unit |
N/A PC |
Short Description |
N/A PNOZ s6.1 48-240VACDC 3 n/o 1 n/c |
Certifications |
N/A European Conformity (CE), Tested to Canadian and US standards by Underwriters' Laboratories (cULus) Listed, EAC (Eurasian), TÜV, KOSHA, CCC |
Application Options |
N/A Simultaneity Monitoring, Two-Hand Monitoring Type III A |
Current at DC1 [Max] |
N/A 6.0 A |
Voltage at AC1 |
N/A 240 V |
Terminal Type |
N/A Screw Terminal |
Terminal Style |
N/A Plug-in |
Stop Category |
N/A 0 |
Standards |
N/A European Standard (EN) 574 TYP III A, European Standard (EN) 60204-1, European Standard (EN) 62061, European Standard (EN) International Organization for Standardization (ISO) 13849-1, VDE 0113-1 |
Operating Modes |
N/A Dual-Channel, Detection of Shorts Across Contacts |
Alternating Current (AC) Supply Voltage |
N/A 48.0 to 240.0 V |
Direct Current (DC) Supply Voltage |
N/A 48.0 to 240.0 V |
Gross Weight |
N/A 215 g |
Net Weight |
N/A 205 g |
Ambient Temperature [Min] |
N/A -10 ºC |
Ambient Temperature [Max] |
N/A 55 ºC |