The safety relays PNOZ s5 and PNOZ s9 can be used as timer relays for monitoring emergency stop, safety gate or light grid. The timer relay PNOZ s5 is a base unit and it has a de-energization. The safety relay PNOZ s9 can be used as a delay-on de-energization, delay-on energization, or pulsing timer relay. It can also be used in connection with a base unit as a delayed or instantaneous contact expansion.
PNOZsigma 22.5 mm Width Time Monitoring Safety Relay (750105)
Unit of Measure
Items PNOZsigma 22.5 mm Width Time Monitoring Safety Relay (750105)
750105
PNOZsigma 22.5 mm Width Time Monitoring Safety Relay
List Price QUOTE
PNOZsigma 17.5 mm Width Time Monitoring Safety Relay (750109)
750109
PNOZsigma 17.5 mm Width Time Monitoring Safety Relay
List Price QUOTE
PNOZsigma 22.5 mm Width Time Monitoring Safety Relay (750135)
750135
PNOZsigma 22.5 mm Width Time Monitoring Safety Relay
List Price QUOTE
PNOZsigma 22.5 mm Width Time Monitoring Safety Relay (751105)
751105
PNOZsigma 22.5 mm Width Time Monitoring Safety Relay
List Price QUOTE
PNOZsigma 17.5 mm Width Time Monitoring Safety Relay (751109)
751109
PNOZsigma 17.5 mm Width Time Monitoring Safety Relay
List Price QUOTE
Description N/A PNOZsigma Safety relay (standalone). Inputs: 1-/2-channel wiring with/ without detection of shorts across contacts. Outputs: 2 N/O, 2 N/O (t = 0 - 300s), 1 semiconductor UB 24 VDC, width: 22.5 mm, plug-in terminals of screw type Monitoring E-STOP, safety gates. N/A PNOZsmart Safety relay (standalone). Inputs: 1-channel wiring possible Outputs: 3 N/O, 1 N/C (t = 0-300 s). UB 24 VDC, width: 17.5 mm, plug-in terminals of screw type. Contact block and timer for contact expansion in connection with safety-related control components or sequence of a safety-related time function (delay-on energization, delay-on de-energization, pulsing). N/A PNOZsigma Safety relay (standalone). Inputs: 1-/2-channel wiring with/ without detection of shorts across contacts Outputs: 2 N/O, 2 N/O (t = 0 - 300s), 1 semiconductor UB 48 - 240 VAC/DC, width: 22.5 mm, plug-in terminals of screw type Monitoring E-STOP, safety gates. N/A PNOZsigma Safety relay (standalone). Inputs: 1-/2-channel wiring with/ without detection of shorts across contacts Outputs: 2 N/O, 2 N/O (t = 0 - 300s), 1 semiconductor UB 24 VDC, width: 22.5 mm, plug-in spring-loaded terminals. Monitoring E-STOP, safety gates. N/A PNOZsigma Safety relay (standalone). Inputs: Single-channel wiring. Outputs: 3 N/O, 1 N/C (t = 0 - 300 s). UB 24 VDC, width: 17.5 mm, plug-in spring-loaded terminals. Contact block and timer for contact expansion in connection with safety-related control components or sequence of a safety-related time function (delay-on energization, delay-on de-energization, pulsing).
Type N/A Monitoring Safety Relay N/A Monitoring Safety Relay N/A Monitoring Safety Relay N/A Non-Coated Version Safety Monitoring Relay N/A Non-Coated Version Safety Monitoring Relay
Certifications N/A European Conformity (CE), Tested to Canadian and US standards by Underwriters' Laboratories (cULus) Listed, EAC (Eurasian), TÜV, KOSHA, CCC
Application Options N/A Instantaneous Emergency Stop Monitoring, Limit Switch, Light Beam Device monitor Type 2 with t/p, Light Beam Device Monitor Type 2 without t/p, Light Beam Device monitor Type 4, Safety Gate Monitor, Safe Delay-on de-Energization Timer, Delayed Emergency Stop Monitoring N/A Instantaneous Contact Expansion, Delayed Contact Expansion, Safe Delay-On De-Energization Timer, Safe Delay-On Energization Timer, Safe Pulsing Timer N/A Instantaneous Emergency Stop Monitoring, Limit Switch, Light Beam Device monitor Type 2 with t/p, Light Beam Device Monitor Type 2 without t/p, Light Beam Device monitor Type 4, Safety Gate Monitor, Safe Delay-on de-Energization Timer, Delayed Emergency Stop Monitoring N/A Instantaneous Emergency Stop Monitoring, Limit Switch, Light Beam Device monitor Type 2 with t/p, Light Beam Device Monitor Type 2 without t/p, Light Beam Device monitor Type 4, Safety Gate Monitor, Safe Delay-on de-Energization Timer, Delayed Emergency Stop Monitoring N/A Instantaneous Contact Expansion, Delayed Contact Expansion, Safe Delay-On De-Energization Timer, Safe Delay-On Energization Timer, Safe Pulsing Timer
Operating Modes N/A Single-Channel, Automatic Reset, Dual-Channel, Manual Reset, Detection of Shorts Across Contacts, Start-Up Testing, Monitored Manual Reset, without Detection of Shorts Across Contacts, Self Test, Prog. Delay-on De-Energization N/A Single-Channel N/A Single-Channel, Automatic Reset, Dual-Channel, Manual Reset, Detection of Shorts Across Contacts, Start-Up Testing, Monitored Manual Reset, without Detection of Shorts Across Contacts, Self Test, Prog. Delay-on De-Energization N/A Single-Channel, Automatic Reset, Dual-Channel, Manual Reset, Detection of Shorts Across Contacts, Start-Up Testing, Monitored Manual Reset, without Detection of Shorts Across Contacts, Self Test, Prog. Delay-on De-Energization N/A Single-Channel
Standards N/A European Standard (EN) 60204-1, European Standard (EN) 62061, European Standard (EN) International Organization for Standardization (ISO) 13849-1, VDE 0113-1, European Standard (EN) 60947-5-1 N/A European Standard (EN) 60204-1, European Standard (EN) 62061, VDE 0113-1 N/A European Standard (EN) 60204-1, European Standard (EN) 62061, European Standard (EN) International Organization for Standardization (ISO) 13849-1, VDE 0113-1, European Standard (EN) 60947-5-1 N/A European Standard (EN) 60204-1, European Standard (EN) 62061, European Standard (EN) International Organization for Standardization (ISO) 13849-1, VDE 0113-1, European Standard (EN) 60947-5-1 N/A European Standard (EN) 60204-1, European Standard (EN) 62061, VDE 0113-1
Direct Current (DC) Supply Voltage N/A 24.0 V N/A 24.0 V N/A 48.0 to 240.0 V N/A 24.0 V N/A 24.0 V
Supply Voltage Type N/A Direct Current (DC) N/A Direct Current (DC) N/A Alternating Current (AC), Direct Current (DC) N/A Direct Current (DC) N/A Direct Current (DC)
Alternating Current (AC) Supply Voltage N/A N/A N/A 48.0 to 240.0 V N/A N/A
Terminal Style N/A Plug-in
Terminal Type N/A Screw Terminal N/A Screw Terminal N/A Screw Terminal N/A Spring-Loaded Terminal N/A Spring-Loaded Terminal
Number of Instantaneous Safety Contacts N/A 2 N/A N/A 2 N/A 2 N/A
Number of Delayed Safety Contacts N/A 2 N/A 3 N/A 2 N/A 2 N/A 3
Number of Auxiliary Contacts N/A 0
Safety Contact Delay Type N/A N/A Delay-On De-Energization, Delay-On Energization, Pulsing N/A N/A N/A Delay-On De-Energization, Delay-On Energization, Pulsing
Number of Delayed Auxiliary Contacts N/A N/A 1 N/A N/A N/A 1
Auxiliary Contact Delay Type N/A N/A Pulsing, Delay-On De-Energization, Delay-On Energization N/A N/A N/A Pulsing, Delay-On De-Energization, Delay-On Energization
Number of Semiconductor Outputs N/A 1 N/A N/A 1 N/A 1 N/A
Selectable Times N/A 0.04 s0.10 s0.20 s0.30 s0.40 s0.50 s0.60 s0.70 s0.80 s1.00 s1.50 s2.00 s2.50 s3.00 s3.50 s4.00 s5.00 s6.00 s7.00 s8.00 s10.00 s12.00 s14.00 s15.00 s16.00 s20.00 s25.00 s30.00 s35.00 s40.00 s50.00 s60.00 s70.00 s80.00 s90.00 s100.00 s120.00 s140.00 s150.00 s160.00 s180.00 s200.00 s210.00 s240.00 s300.00 s
Stop Category N/A 0 1
Current at DC13 I (6 cycles/min) [Max] N/A 4.0 A N/A 5.0 A N/A 4.0 A N/A 4.0 A N/A 5.0 A
Current at AC15 [Max] N/A 3.0 A N/A 5.0 A N/A 3.0 A N/A 3.0 A N/A 5.0 A
Width N/A 22.5 mm N/A 17.5 mm N/A 22.5 mm N/A 22.5 mm N/A 17.5 mm
Height N/A 98.0 mm N/A 98.0 mm N/A 98.0 mm N/A 100.0 mm N/A 100.0 mm
Depth N/A 120.0 mm
Gross Weight N/A 245 g N/A 185 g N/A 260 g N/A 245 g N/A 185 g
Net Weight N/A 235 g N/A 175 g N/A 250 g N/A 235 g N/A 175 g
Ambient Temperature [Min] N/A -10 ºC N/A -15 ºC N/A -10 ºC N/A -10 ºC N/A -15 ºC
Ambient Temperature [Max] N/A 55 ºC
Contact Configuration N/A 2 Normally Open (N/O), 2 Normally Open (N/O) N/A 3 Normally Open (N/O), 1 Normally Closed (N/C) N/A 2 Normally Open (N/O), 2 Normally Open (N/O) N/A 2 Normally Open (N/O), 2 Normally Open (N/O) N/A 3 Normally Open (N/O), 1 Normally Closed (N/C)
Available Status N/A On Request
Quantity N/A 1
Unit N/A PC
Short Description N/A PNOZ s5 24VDC 2 n/o 2 n/o t N/A PNOZ s9 24VDC 3 n/o 1 n/c t N/A PNOZ s5 48-240VACDC 2 n/o 2 n/o t N/A PNOZ s5 C 24VDC 2 n/o 2 n/o t N/A PNOZ s9 C 24VDC 3 n/o 1 n/c t
Note N/A Call for current pricing.
Optional Accessories N/A 750010, Connector (QUOTE)
750900, Accessory (QUOTE)
750910, Pulse Expansion (QUOTE)
751004, Set of Plug-In Replacement Terminal (QUOTE)
N/A 750003, Set of Plug-In Replacement Terminal (QUOTE)
750020, Connector (QUOTE)
N/A 750004, Set of Plug-In Replacement Terminal (QUOTE)
750010, Connector (QUOTE)
750900, Accessory (QUOTE)
750910, Pulse Expansion (QUOTE)
N/A 750010, Connector (QUOTE)
750900, Accessory (QUOTE)
750910, Pulse Expansion (QUOTE)
751004, Set of Plug-In Replacement Terminal (QUOTE)
N/A 750020, Connector (QUOTE)
751003, Set of Plug-In Replacement Terminal (QUOTE)